|
|
|
|
 |
|
|
|
|
|
 |
|
ȸ»ç¸í |
¼Û¾Ï½Ã½ºÄÞ(ÁÖ) |
SONGAM SYSCOM CO., LTD. |
´ëÇ¥ÀÚ |
 ÀÌÇØ±Ô |
ȨÆäÀÌÁö |
www.songam.co.kr |
Lee Hae Kyou |
ÁÖ¼Ò |
°¿øµµ ¿øÁֽà ¹®¸·À¾ µ¿È°ø´Ü·Î 32 |
32 Donghwa-gongdanro, Moonmak-eup, Wonjoo-city, Gangwon-do, Korea |
|
|
 |
|
¼Û¾Ï½Ã½ºÄÞÀº Àü·ÂÀüÀÚ¿Í Åë½ÅÀü¹®±â¾÷À¸·Î 1991³â ¼³¸³µÈ ÀÌ·¡ 23³â°£ Àü·Â»ê¾÷ÀÇ ½º¸¶Æ®È¸¦ Ãß±¸ÇؿԽÀ´Ï´Ù. Àü·ÂÀüÀÚ °¨½ÃÁ¦¾î, ³×Æ®¿öÅ© Åë½Å ¹× ÅëÇÕÀåÄ¡ µî ½º¸¶Æ®±×¸®µå ½Ã´ëÀÇ Network Infra¿¡ ÇÊ¿äÇÑ ÃÖ°í¼öÁØÀÇ Á¦Ç°À» °ø±ÞÇÏ¿© Àü±âǰÁú Çâ»óÀº ¹°·Ð Àü·Â»ý»ê ¿ø°¡Àý°¨ µî Àü·Â¼³ºñ ¿î¿ë±â¼ú ¹ßÀüÀ» À§ÇØ ³ë·ÂÇϰí ÀÖ½À´Ï´Ù.
¾ÕÀ¸·Îµµ IEC 61850À» ±â¹ÝÀ¸·Î ÇÏ´Â Â÷¼¼´ë ¼Ûº¯Àü¼ÒÀÇ ¿î¿µ½Ã½ºÅÛ, ½º¸¶Æ®±×¸®µå Àü·ÂÅë½Å¸Á ÅëÇÕÇ÷¿Æû µî À¯ºñÄõÅͽº ±â¼úÀ» Á¢¸ñÇÑ Àü·ÂITÀÇ ¹Ì·¡ »ê¾÷ȯ°æ°ú Áö´ÉÇü Àü·Â¸Á ±â¹ÝÀÇ Àúź¼Ò ³ì»ö¼ºÀåÀ» Á¦½ÃÇÏ¸ç ¼³ºñÀÇ ³ôÀº ½Å·Úµµ´Â ¹°·Ð, °øÁ¤Çϰí Åõ¸íÇÑ ±â¾÷ ½Å¿ëÀ» ¹ÙÅÁÀ¸·Î °í°´ ¸¸Á·À» À§ÇØ °è¼Ó ³ë·ÂÇϰڽÀ´Ï´Ù
|
Since established 1991, Songam has been the best partner of KEPCO for monitoring & controlling and communication equipment with its leading technical and marketing capability for more than 23 years.
As a pioneer of electric power and ICT convergence, Songam is concentrating all its efforts on developing core technologies and next generation products for "Smart Grid", a green technology of 21st century |
|
|
 |
|
-Tiny Optic DCU
ÀüÀÚ½Ä Àü·Â·®°è¿Í Åë½ÅÇÏ¿© °í°´ÀÇ Àü±â»ç¿ëÁ¤º¸¸¦ ¼öÁý, ÀúÀåÇÏ°í ¼¹öÀÇ ¸í·ÉÀ» ÀÔ·Â ¹Þ¾Æ Àü·Â·®°è¿¡ ¼³Á¤ ¹× ¸ð´ÏÅ͸µ ±â´ÉÀ» Á¦°øÇϸç, »óÀ§ ½Ã½ºÅÛÀÎ FEP ¹× AMR ¼¹ö¿Í »óÈ£ Åë½ÅÇÏ¿© ¼öÁýµÈ Àü·Â·®°è Á¤º¸¸¦ Àü´Þ, ¼³Á¤ ¹× °ü¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. ±¤ ÀÎÅÍÆäÀ̽º(IEC 62439-3) ³»ÀåÇÏ¿© ±âÁ¸ÀÇ AMI Á¤º¸ ¼öÁýÀ» À§ÇØ ±¸ÃàµÈ Àü·Â¼±Åë½Å(PLC), ¹«¼± Mesh½ÅÈ£¸¦ ±¤ ÀÌ´õ³Ý ½ÅÈ£·Î º¯È¯ÇÏ¿© Àü¼ÛÇÕ´Ï´Ù.
-AMI(PLC) tester
ÀüÀÚ½Ä Àü·Â·®°è¿¡ ¿¬°áÇÏ¿© °è±âÀÇ ID, BPS(Bit per Symbol) µî °¢Á¾ Á¤º¸¸¦ È®ÀÎÇÏ¿© µ¿ÀÛ »óÅ ¹× ¼º´ÉÀ» Á¡°ËÇÏ´Â ÀåºñÀÔ´Ï´Ù. ¼ÒÇü °æ·®ÈÇÏ¿© ÈÞ´ë°¡ °£ÆíÇϸç ÇöÀå¿¡¼ °è±âÀÇ »óŸ¦ Áï½Ã È®ÀÎÇÏ¿© Á¶Ä¡¸¦ ÇÒ ¼ö ÀÖµµ·Ï ÇØÁÝ´Ï´Ù. ÅëÇÕ Çü Áö±× º¸µå¸¦ Ç¥ÁØÇü/G-Type/E-Type °è±â¿¡ ÀåÂøÇÏ¿© º» Á¡°Ë ÀåÄ¡¿¡ ¿¬°áÇÏ¿© »óŸ¦ Á¡°ËÇÒ ¼ö ÀÖÀ¸¹Ç·Î ¸ðµç ÇöÀå¿¡¼ °è±â Á¡°Ë ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù
-HSR Switch
½º¸¶Æ®±×¸®µå Åë½Å¸Á ±¸Ãà¿¡ ÀûÇÕÇÑ Àåºñ·Î, ´Ù¾çÇÑ ´Ü¸» ¹× ³×Æ®¿öÅ© ÀåºñµéÀ» ¼ö¿ëÇÒ ¼ö ÀÖµµ·Ï ´Ù¾çÇÑ Åë½Å ÀÎÅÍÆäÀ̽º¸¦ Á¦°øÇϸç, IEC 62439-3Ç¥ÁØÀÇ HSRÀ» Àû¿ëÇÏ¿© °í½Å·Ú¼ºÀ» º¸ÀåÇÕ´Ï´Ù. 100Mbps ¶Ç´Â 1Gbps±ÞÀÇ ±¤ ¼±·Î¸¦ ÀÌ¿ëÇÑ RING ±¸Á¶·Î ±¸¼ºÀÌ °¡´ÉÇϸç, ÇÑÂÊ ¹æÇâÀÇ ³×Å©¿öÅ© Àå¾Ö ½Ã Zero recovery TimeÀ» °¡Áö°í Packet ¼Õ½Ç ¾øÀÌ ¿Ïº®ÇÏ°Ô Àýü¸¦ ÇÔÀ¸·Î ½Ç½Ã°£ ¼ø´Ü¾ø´Â ¼ºñ½º Á¦°øÀÌ °¡´ÉÇÕ´Ï´Ù.
|
Advanced Metering Infrastructure(AMI) Total Solution
- Tiny Optic DCU : A built-in optical interface(IEC 62439-3) data concentrator unit
Powerline communication (ISO/IEC 12139-1)
- AMI Tester : Multi tester for electricity meter (IEC 62056)
ID check, BPS(Bit per Symbol) check, Cable test
For every type of electricity meter (Standard, G-Type, E-Type, Multi)
- HSR Switch : Redundant Optical Switch for high reliable network
Packet lossless communication
High-availability Seamless Redundancy (IEC 62439-3)
|
|
|
 |
|
|
|
 |
|
|
|
|
|
|
|