Âü°¡½Åû Âü°¡¾÷üÇöȲ
 È¸»ç¸í  ÇǴнºÅ×Å©´Ð½º
 Phoenix Technologies
 ´ëÇ¥ÀÚ  ±èÇöºÀ  È¨ÆäÀÌÁö  www.phoenixtech.kr
 Kim Hyun Bong
 ÁÖ¼Ò  ¼­¿ï ¸¶Æ÷±¸ »ó¾Ïµ¿ 1649 DMC »êÇÐÇù·Â¿¬±¸¼¾ÅÍ 605È£
 Suite 605, DMC R&D Center 1649 Sangam-Dong, Mapo-Gu, Seoul 121-904, Korea
Æó»çÀÇ »ç¾÷ǰ¸ñÀÎ °æº¸Ç¥½ÃÀåÄ¡[Annunciator]´Â ´ëÇѹα¹ÀÇ 30¿©³â ¿øÀڷ¹ßÀü¼Ò ¿ª»ç¿Í ÇÔ²² Çϰí ÀÖÀ¸¸ç, °íÀå±â·ÏÀåÄ¡ [Fault Monitoring System]¿Í °¨¸¶¼±À» ÀÌ¿ëÇÑ ¸ôµå·¹º§ [Nuclear Mold Level] ÀåÄ¡´Â ±¹³»¿Ü °¢Á¾ Ç÷£Æ® °ø»ç¸¦ ÅëÇØ °ËÁõµÇ¾î ¿Â ½Å·Ú¼ºÀÌ ¸Å¿ì ¿ì¼öÇÑ Á¦Ç°À¸·Î¼­ ÇöÀç±îÁöµµ ¾çÈ£ÇÑ µ¿ÀÛÀ¸·Î ¼³ºñÀÇ È¿À²¼ºÀ» ±Ø´ëÈ­Çϰí ÀÖ½À´Ï´Ù. ¶ÇÇÑ »ê¾÷ ¹× ÇØ¾ç»ê¾÷¿ë UPS¿Í Àü·Â °ú±Ý¿ë °è±â¸¦ »õ·Ó°Ô ¼±º¸ÀÌ°Ô µÇ¾ú½À´Ï´Ù. Ç÷£Æ®ÀÇ °¢ ºÐ¾ß¿¡¼­ ¿À·£ ½Ç¹«°æÇè°ú ÀÌ·ÐÀ» °âºñÇÑ ´Ù¼öÀÇ ÇÙ½É Àü¹®°¡Á¶Á÷ÀÌ °í°´¸¸Á·À» À§ÇØ 24½Ã°£ ÃÖ¼±ÀÇ ¼­ºñ½º¸¦ ¼öÇàÇϰí ÀÖ½À´Ï´Ù.
The flagship item of Phoenix Technologies 'annunciator' is in tandem with the history of Korea's nuclear power generation which spans some three decades. Fault Monitoring System and Mold Level System with Gamma ray are recognized for its industry-proven reliability and performance through an integral part of plant operations, helping to maximize the efficiency of the facilities till now. In addition, we are ready to introduce UPS for industrial and Marine and Tariff meter for electric power.
A team of specialists and experts with years of experience and cutting-edge knowledge in each field of the plant industry is doing the best service 24 hours to be satisfied customers.
Ç÷£Æ® °æº¸Ç¥½ÃÀåÄ¡ (Annunciator): Ç÷£Æ®ÀÇ ÁÖ¿ä¼³ºñ(¹ßÀü±â Àüµ¿±â µîÀÇ ÇٽɺÎǰ)¿¡ °íÀå ¶Ç´Â ÀÌ»óÀÌ ¹ß»ýÇϸé ÁÖÁ¦¾î½Ç(MCR) ¶Ç´Â ÇöÀåÁ¦¾î¹Ý(Local Control Panel)ÀÇ ¿î¿µÀÚ¿¡°Ô Áï½Ã ½Ã°¢ ¹× û°¢À¸·Î ±¸Ã¼ÀûÀÎ °æº¸¸¦ ¹ß»ýÇÏ¿© Ç÷£Æ® ¼³ºñ¸¦ °¨½ÃÇÏ´Â ÀåÄ¡
ºñÁ¢Ã˽ķ¹º§ÃøÁ¤½Ã½ºÅÛ(Level Measurement System): ÃøÁ¤±â´Â ¹æ»ç¼±À» ÀÌ¿ëÇÑ ¹æ½ÄÀ¸·Î Å©°Ô ¼±¿øºÎ¿Í °ËÃâºÎ ±×¸®°í °ËÃâÇÑ °ªÀ» µðÁöÅÐ ½ÅÈ£·Î ¹Ù²Ù¾î ÁÖ´Â µðÁöÅнÅÈ£ 󸮺ηΠ±¸¼ºµÇ¸ç ¼±¿øºÎ¿¡ ¹æ»ç¼º¹°Áú(Cs-137)À» ÀÌ¿ëÇÏ¿© °¨¸¶¼±À» ¹ß»ý ½ÃÄÑ ±× ½ÅÈ£¸¦ ¹Ý´ëÆíÀÇ °ËÃâºÎÀÇ ¼¶±¤Ã¼¸¦ ÀÌ¿ëÇÏ¿© °¨¸¶¼±À» ºûÀÇ ½ÅÈ£·Î º¯È¯, °¢°¢ÀÇ ÁöÁ¡¿¡¼­ÀÇ ¼¼±â¸¦ Àü±âÀû½ÅÈ£·Î ¹Ù²Ù°í ÀüÀÚȸ·Î¸¦ ÅëÇØ µðÁöÅÐ ½ÅÈ£·Î ¹Ù²Ù¾î ¹è°ü ³»ºÎÀÇ Á¤È®ÇÑ ¿ëÇØ¾× ·¹º§À» °èÃøÁ¦¾î°¡ °¡´É. ¹æ»ç¼±À» ÀÌ¿ëÇϹǷΠ¿ë±â³ª ³»ºÎÀÇ ÀçÁú¿¡ ¿µÇâÀ» ¹ÌÄ¡Áö ¾Ê°í Á¤È®ÇÑ °ªÀ» ÃøÁ¤ÇÏ´Â ½Ã½ºÅÛ
°íÀå±â·ÏÀåÄ¡(Fault Monitoring System) DFR(Digital Fault Recorder): ÁÖ·Î ¹ßÀüÇ÷£Æ®ÀÇ Àü·Â°èÅëÀÌ»óÀ» °¨Áö/±â·ÏÇÏ¿© ºÐ¼®ÇÒ ¼ö ÀÖµµ·Ï ÇØÁÖ´Â ÀåÄ¡. DFR°ú ½Ã½ºÅÛÀ» ÅëÇÕÇÏ¿© FMS (Fault Monitoring System)¸¦ ±¸¼º. 1 Cycle ´ç 512 Sampling rate·Î ÀúÀåÀÌ °¡´ÉÇÏ¸ç ¸Å¿ì Á¤È®ÇÑ ÃøÁ¤ ¹× ºÐ¼® ÀÌ °¡´É. ¿É¼ÇÀ¸·Î½á Á¤È®µµ ¡¾ 60 meters (200 feet)ÀÇ °íÀåÁöÁ¡ºÐ¼® ±â´ÉÀÌ ÀÖÀ¸¸ç, FAN¾ø´Â ÀåÄ¡±¸¼ºÀ¸·Î Àú¼ÒÀ½, ÀúÀü·Â ±¸ÇöÀÌ °¡´É. ¶ÇÇÑ, ¸ðµç µ¥ÀÌÅÍ ´Â Compact Flash¿¡ ÀúÀå.
Manometer: ¾Ð·ÂÃøÁ¤°ú Áø°øÀÇ Â÷¾ÐÀ» ÃøÁ¤ÇÏ´Â µ¥¿¡ ÀÖ¾î, °æÁ¦ÀûÀÎ ´Ù ¿ëµµ°è±â. UÀÚ°ü ŸÀÔÀÇ ¾Ð·Â°è´Â ¾Ð·ÂÃøÁ¤¿¡ ÀÖ¾î ±âº»ÀûÀÎ ±Ô°Ý. ¾Ð·ÂÃøÁ¤Àº À¯µ¿Ã¼°¡ °¡¸®Å°´Â À­ºÎºÐÀÌ ¼öÁ÷À¸·Î ±ÕÇüÀÌ ÀÌ·ç¾îÁ³À» ¶§ ÀÌ·ç¾îÁü. ¾Ð·Â°è¿¡, Á¶ÀÛÀ» À§ÇÑ Ä·À̳ª ±â¾î, ·¹¹ö°¡ ¾ø¾îµµ Á¤È®ÇÑ ÃøÁ¤ÀÌ °¡´É. °øÁ¤À̳ª Á¦Ç°ÀÇ Å×½ºÆ® ¸ñÀûÀ» À§ÇÏ¿© °í¾ÈµÈ ¾Ð·Â°è·Î¼­, Á¤È®ÇÑ ´«±Ý°ªÀ» Áö½ÃÇØÁÖ¸ç ¾Ð·ÂÀÇ ½ÇÇè¿ë ÃøÁ¤, Áø°øÀÇ ¾Ð·ÂÂ÷ ÃøÁ¤¿¡ »ç¿ë
Industrial & Marine UPS / Tariff Power Meter
Plant Annunciator: The latest generation of state-of-the-art annunciators offered in window models. The Annunciator is designed for the process and power industries' requirements, providing the most economical approach while offering the most advanced data acquisition in serial technology and monitoring, along with high quality and performance standard.
Level Measurement System: is ideally suited for continuous level measurement of liquids and solids contained in a vessel without making contact with the process material. Since all system components are not wetted to the process, the continuous on-line level measurement can be made regardless of such conditions as extreme temperature, high pressure, and corrosive, toxic or abrasive materials within the vessel.
Fault Monitoring System: comprehensive power system monitoring from a single multifunction device to maximize the utilization of the power network at minimum cost. Ideal for use in substations and generating stations
 Utilizes the most accurate measurement chain including sampling rate of 512 samples per cycle and analog resolution of 20 bits on current channels
 Option of travelling wave fault location with accuracy of ¡¾60 meters (200 feet)
 Achieve cost effective, integrated, automated substation integration with IEC 61850
 Full solid state device and high reliability - all data stored on CompactFlash

Manometer: Users can view up to four measurements simultaneously on the high resolution LCD or compare HART PV and AO values to corresponding values measured by the NIST traceable MFT. Available modules include differential, gauge, vacuum and absolute pressure as well as temperature and voltage/current. A voltage and current meter is integral to the base unit. All HART field devices can be configured, polled and trimmed using HART communications. Device Specific commands for supported devices are included with the MFT.
Industrial & Marine UPS / Tariff Power Meter